Shaft Elongation in Vertical Pumps

The elongation of a vertical pump shaft is caused by three separate phenomena:
  1. The tensile stress caused by the weight of the rotor.
  2. Tensile stress caused by axial thrust
  3. The thermal expansion of the thrust
In most cases the tensile stress created by the axial thrust is several times greater than that created by the weight. In typical example of a 16,000 gpm pump designed for a 175-ft head and 5o ft long, the elongation caused by the weight of a 1600 lb (726 kg) impeller will be of the other of 0.0033 in. The elongation caused by the axial thrust will be approximately 0.0315 in.

The elongation caused by thermal expansion has to be considered from two angles. Firs, if the shaft and the stationary parts are built of materials that have essentially the same coefficient of expansion, both will expand equally and no significantly the same range of temperature in which they were assembled, no significant relative expansion will take place, even if dissimilar coefficients expansion are involved. Whatever the case, the pump manufacturer take these factors into consideration by providing the necessary vertical and play between the stationary and rotating pump components.

Load of foundations of Vertical Pumps

It the motor support is integral with the pump discharge column, and if the hydraulic thrust is carried by the motor thrust bearing, this thrust is not additive to the deadweight of the pump and of its motor plus the weight of the water contained in the pump, insofar as the load on the foundations is concerned. This is because the pump and motor mounted in this fashion form a self contained entity and all internal forces and stresses are balanced within the entity. If the pump and motor is supported separately, however, and joined by rigid coupling that transmits the pump hydraulic thrust to the motor thrust bearing, the foundation will carry the following heads when the pump is running.

Wednesday, May 13, 2009

Axial Thrust in Vertical Pumps

Axial Thrust in Vertical Pump With Single Suction Impeller . The subject of axial thrust in horizontal pumps has already discussed in my article before. When pumps are installed in a vertical position, additional factors need be taken into account when determining the amount and direction of the thrust to be absorbed in the thrust bearings.

The first and most significant of these factors is the weight of the rotating parts, which is a constant downward force for any given pump, completely independent of the pump operating capacity or total head. Since in most cases the single suction impellers of vertical pumps are mounted with the suction eye facing downward, the normal hydraulic axial thrust is exerted downward and the weight of the rotating parts is additive to this axial thrust.

The second factor involves the dynamic force (or change in momentum) caused by the change in the direction of flow, from vertical to either horizontal or partly horizontal, as the pumped liquid flows through the impeller. This force acts upward and balances a small for water having a specific weight (force) of 62.34 lb/ft2.

Wednesday, April 29, 2009

The Application of Vertical Wet-Pit Pump

Like all pumps, the vertical wet-pit pump has advantages and disadvantages. One disadvantage is that installation does not require a separate dry pit to collect the pumped liquid. If the impeller (first-stage impeller in multistage pumps) is submerged, no priming problem exists and the pump can be automatically controlled without fear of its ever running dry. Moreover, the available NSPH is greater (except in closed tanks) and often permit in higher rotative speed for the same service conditions. A second advantage is that the motor or driver can be located at any desired height above fixed level.

 

It has the following mechanical disadvantages:

  1. the possibility of freezing whom idle
  2. similar installation
  3. the inconvenient of lifting out and dismantling of inspection and repair, no matter how small
  4. the pump bearing have a relative short life unless the water and bearing design are ideal.

 

In the summary the vertical wet-pit pump is the best pump available for some applications. Its not ideal be the most economical for certain installations, a poor for some, and the least desirable for still others,

 

Monday, April 27, 2009

Volute Pump

A variety of wet pit pumps are available. The liquid pumped, be it clean water, sewage, abrasive liquids or slurries, dictates whether a semi open or an enclosed impeller will be used, whether the shafting will be open or closed to the liquid pumped, and whether the bearings will be submerged or located above the liquid.

A single volute pump with a single suction enclosed nonclog impeller, no pump-out vanes or wearing ring joints on the back side of the impeller, and enclosed shafting. The pump is design to be suspended from an upper floor by means of a drop pipe and for pumping sewage or other solid laden liquids. To seal against leakage along the shaft at the point where it passes through the casing, a seal chamber or a stuffing box is provided.

In most application these volute pumps have been replaced with vertical wet-pit pump with the stuffing box/seal chamber in the discharge head. This pump is suitable for pumping heavy concentration of solid material (such as sludge or slurries) or in certain food processing application, but other type of impeller can be substituted. Pumped liquid leakage from casing is relieved back to the suction through holes in the support pipe. The seal chamber or stuffing box at the driver floor elevation is used only when gas tight construction is desired. The lower and any intermediate sleeve bearing are grease-lubricated as shown, but gravity feel oil lubrication is also available in other design. The upper anti friction thrust bearing is grease-lubricated. A solid shafts motor and flexible shaft are used.

An interesting design of the wet-pit pump uses a single stage, double suction impeller in a twin volute casing. Because the axial thrust is billings are externally lubricated, either with oil or with water. The lower bearing its lubricated from an external pipe connection.

Sunday, April 12, 2009

Bases and Support for Vertical Pump

Vertical shaft pumps like horizontal shaft units, must be firmly supported. Depending upon the installation, the unit can be supported at one or several elevations. Vertical unit are seldom supported from walls, but even that type of support to sometimes encountered.

Occasionally, a nominal horizontal shaft pump design is arranged with a vertical shaft and a wall used as the supporting foundation. Regular horizontal shaft units can be used for this purpose without modification, except that the blade-plate is attached to a wall. Careful attention must be given to the arrangement to the pump bearings to prevent the escape of the lubricant. Installation of double suction, single-stage pumps with the shaft in the vertical position are relatively rare, except in some marine or navy applications. Hence, manufacturers have few standard pumps of the kind arrangement so that a portion of the casing forms the support (to be mounted pumps on soleplantes).

Wednesday, April 8, 2009

Vertical Single Suction Pump

Vertical single suction pumps with bottom suction are commonly used for larger sewage, water supply or condenser circulating applications. Such pumps are provided with wing feet that are bolted to soleplates grouted in concrete pedestal or piers. Sometimes the wing feet may be grouted right in the pedestal. This must be suitably arranged to provide proper access to any handholes in the pump and to allow clearance for the elbow suction nozzle if these are used.

If a vertical pump is applied to a condensate service or some other service for which the eye of the impeller must be vented to prevent vapor binding, a pump with a bottom single inlet impeller is not desirable because it does not permit effective venting. Neither does vertical pump employing a double suction impeller. The most suitable design for such applications incorporate a top single inlet impeller.

If the driver of a vertical pump can be located immediately above the pump, it is often supported on the pump itself. The shaft of the pump and driver may be connected by flexible coupling, which required that each have its own thrust bearing. If the pump shaft is rigidly coupled to the driver shaft or an extension of the driver shaft, a common thrust bearing is used, normally in the driver.

Although the driving motors are frequently mounted on top of the pump casing, one important reason for the use of the vertical shaft design is the possibility of locating the motors at an elevation sufficiently above the pump to prevent the accidental flooding of the motors. The pump and its driver may be separated by an appreciable length of shafting, which may required already bearing between the two units.

Bearings for vertical dry-pit pumps and for intermediate guide bearings are usually antifriction grease lubricated types to simply the problem of retaining a lubricant in a housing with a shaft projecting vertically through it. Larger units, for which antifriction bearing are not available or desirable, use self-oiling Babbitt steady bearings with spiral oil grooves. The pump is connected by rigid coupling to its motor which is provided with a line and a thrust bearing.

Tuesday, April 7, 2009

Vertical Pump

Vertical shaft pump fall into two classifications: dry-pit and wet-pit. Dry pit pumps are surrounded by air, the wet-pit types are either fully or partially submerged in the liquid handled.

Vertical Dry-pit Pumps

Dry pit pumps with external bearings include most small, medium, and large vertical pumps, most medium and drainage and irrigation pumps for medium and high heads, many large condenser circulating and water supply pumps, and many marine pumps. Sometimes the vertical pumps is preferred (especially for marine pumps) because it saves floor space. At other time it is desirable to mount a pump at a low elevation because of suction conditions, and it is also preferable or necessary to have the pump driver at a high elevation. The vertical pump is normally used for large capacity applications because it is more economical than the horizontal type, all factor considered.

Many vertical dry-pit pumps are basically designs with minor modifications (usually in the bearings) to adapt them for vertical shaft drive. This is not true of small and medium sized sewage pumps, however. In this units, purely vertical design in the most popular. Most of these sewage pumps have elbow suction nozzle because of their suction supply is usually taken from a wet well adjacent to the pit in which the pump is installed. The suction elbow usually contains a handhole with a removable cover to provide easy access to the impeller.

The dismantle one of these pumps, the stuffing box head must be unbolted from the casing after the intermediate shaft or the motor and motor stand have been removed. The motor assembly is drawn out upward, complete with the stuffing box head, the bearing housing and the like. This rotor assembly then be completely dismantled at a convention location.

Sunday, August 3, 2008

Vertical Pumps

In the chemical Industry, the term vertical process pump generally applies to a pump with a vertical shaft having a length from drive and to impeller of approximately 1 m (3.1 ft) minimum to 20 m (66 ft) or more. Vertical pumps are used either wet-pit pumps (immersed) or dry-pit pumps (externally mounted) in conjunctive with stationary or mobile tanks containing difficult to handle liquid.

They have the following advantages:

  • The liquid level is above the impeller
  • The pump is thus self-priming
  • The shaft seal is above the liquid level and is not wetted by the pumped liquid which simplifies the sealing task (a safety consideration for highly corrosive or toxic liquid)
  • The vertical wet-pit pump may be the only logical choice.

These pumps have the following disadvantages:

  • Intermediate or line bearing are generally required when the shaft length exceeds about 3 m (10 ft). In order to avoid shaft resonance problem, these bearing must be lubricated whenever the shaft is rotating.
  • Since all wetted parts must be corrosion resistant, low-cost materials may not be suitable for the shaft, column, etc.
  • Maintenance is more costly since the pump are larger and more difficult to handle.
For abrasive service, vertical cantilever designs requiring no line or foot bearings are available. Generally, these pumps are limited to about 1 m (3.1 ft) maximum shaft length.